Pub. 42004-411A
Model 12593-001 Redundant PPI Switching Module Page: 5 of 6
\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-411a.doc
05/08
Maintenance
If the module requires service, contact your Regional Service Center for a return authorization number
(RA#). The module should be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number. If the module is under warranty, repairs or a replacement will be made in
accordance with GAI-Tronics’ warranty policy. Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.
Call 800-492-1212 inside the USA or 610-777-1374 outside the USA for help identifying the Regional
Service Center closest to you.
Troubleshooting
Problem Solution
SmartSeries station faults are
present in the secondary system.
Verify 12 V dc power is applied to the module.
Verify CPU PCBA address is set to FF.
Verify cables are properly inserted into connectors J1, J2, J3.
Ensure J1 pins of CPU PCBA are correctly inserted into J4 of
lower relay switching PCBA.
SmartSeries stations squeal
when party line 1 or 2 are
accessed.
Verify connectors J1, J2, J3 are properly inserted. If
disconnected, the page, and party lines 1 and 2 will be
unloaded resulting in oscillation of the SmartSeries handset
amplifier.
Module LEDs do not illuminate
and relays do not switch when
input control is provided.
Verify 12 V dc (-) is being switched to the PRI
and/or SEC
inputs at JTB4
Module still does not function after
all checks described in this section.
Contact GAI-Tronics service for repair or replacement of the
module.