Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 10 of 16
f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc
09/12
TB4 - Audio and Low Voltage Control Terminal Block
The following is a list of connections for the low voltage control and audio signal terminal block, TB4:
Name Pin No. Description
Aux Mic+ 1 Positive terminal for auxiliary microphone (optional).
Aux Mic 2 Negative terminal for auxiliary microphone (optional).
Ext Cont+ 3 Talk/listen control signal for Master/Slave operation.
No connection in Common Line mode.
Ext Cont 4 Ground reference for talk/listen control signal for Master/Slave operation.
No connection in Common Line mode or UNBAL audio configuration.
Shield 5 Ground reference for shield terminations.
Audio+ 6 Positive of the audio line during 600-ohm or 15-kilohm termination
configuration.
Audio 7 Negative of the audio page line during 600-ohm or 15-kilohm termination
configuration.
Footswitch+ 8 Positive of optional auxiliary footswitch operating as local push-to-talk switch.
Footswitch 9 Negative of optional auxiliary footswitch that operating as local push-to-talk
switch.
P1 - Front Cover Wire Harness Connections
Plug in the front cover wire harness connector at P1. Refer to Figure 8.