Parameter Modification PL1877A Microprocessor Radio Telephone Interconnect
12/10 94
Dial Tone Detection
Parameter Function
64 Disable disconnection upon detection of dial tone for a land-line originated call = 0
Enable disconnection upon detection of dial tone for a land-line originated call = 1
Default = 0
General Call Characteristics
Parameter Function
13 Disable mobile call origination = 0
Enable mobile call origination = 1
Default = 1
14 Disable land-line call origination = 0
Enable land-line call origination = 1
Default = 1
15 Disable attendant call origination = 0
Enable attendant call origination = 1
Default = 1
Call Timers
Parameter Function
360 The length of time before disconnect that time out warning ticks are generated.
Valid range = 0–59 seconds.
If this parameter is programmed to 0, time-out ticks are disabled.
Default = 15
Overall Access Timer
Parameter Function
18
Don’t allow mobile user to override access time limit with *** command = 0
Allow mobile user to override access time limit with *** command = 1
Default = 0
19
*** command (entered during conversation) resets overall access timer to 1 minute = 0
*** command (entered during conversation) resets overall access timer to duration
specified by parameter 357 = 1
Default = 1
357 Overall access timer. Valid range = 1–59 minutes.
Any number greater than 59 sets the overall access time to an infinite duration.
Default = 1 minute