Gai-tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telep Instrukcja Użytkownika Strona 94

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 172
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 93
Parameter Modification PL1877A Microprocessor Radio Telephone Interconnect
12/10 88
Telephone Interface
Parameter Function
163 Off-hook voltage threshold is 25 V = 0
Off-hook voltage threshold is 15 V = 1
Allow user to manually set off-hook voltage threshold via test 6 (or programming
software) = 2
Default = 0
This parameter is required for determining the off-hook voltage threshold on the
PL1877A’s phone line. This allows the PL1877A to determine when an attendant (line-
sharing) telephone is in use.
Program parameter 163 to 0 for a phone line that provides a 48 V talk battery.
Program parameter 163 to 1 for a phone line that provides a 24 V talk battery.
If the phone line provides substantially less than 24 V of talk battery, it may be necessary
to manually program the off-hook threshold via test 6 (or via the programming software).
If so, program parameter 163 to 2.
123 Number of rings that PL1877A must receive before generating ring signaling to mobile.
Valid range = 1–9.
Default = 1
This parameter is used to delay ring signaling to the mobile long enough for an attendant
to answer the call via a line sharing telephone.
Przeglądanie stron 93
1 2 ... 89 90 91 92 93 94 95 96 97 98 99 ... 171 172

Komentarze do niniejszej Instrukcji

Brak uwag